Download Print this page

HEIDENHAIN MANUALplus 620 Technical Manual page 546

Hide thumbs Also See for MANUALplus 620:

Advertisement

Parameter
MP number
iTNC MP number
CfgDeadStop
Parameters for traverse to a fixed stop;
Enter the parameters for all axes of the NC channel that are supposed move to a fixed stop.
deadStopLag
403001
(optional parameter)
forthTorqueFactor
403003
(optional parameter)
minTorque
403004
(optional parameter)
maxTorque
403005
(optional parameter)
546
Function and input
Max. permissible following error
This following error limit is effective with the
"traverse to fixed stop" command at constant
velocity.
During acceleration the parameter
CfgPosControl/servoLagMax2 is also in effect
in this operating mode.
Format:
Numerical value
Input:
Following error [mm]
Default:
0.01
Conversion factor of the programmed force to
a torque
Because a maximum force is produced, but
physically only the motor torque can be limited,
the force is converted with this factor to torque.
Format:
Numerical value
Input:
0.1 to 1000
Default:
1
Min. limit of current with quill function
This no-load current (synchronous motor) or rated
current (asynchronous motor) cannot fall below
this percentage.
Format:
Numerical value
Input:
0 to 100 [%]
Default:
20
Max. limit of current with quill function
This no-load current (synchronous motor) or rated
current (asynchronous motor) cannot exceed this
percentage.
Format:
Numerical value
Input:
0 to 100 [%]
Default:
100
HEIDENHAIN Technical Manual MANUALplus 620
Reaction/
Page
Access
RUN
1465
LEVEL3
RUN
1468
LEVEL3
RUN
1469
LEVEL3
RUN
1469
LEVEL3

Advertisement

loading