X6: PLC inputs
272
Pin layout of MB 620T without FS:
Connecting
Assignment
terminals
1
I0
2
I1
3
I2 (control voltage ON, CVO)
4
I3
5
I4
6
I5
7
I6
8
I7
9
Reserved (do not use)
10
Reserved (do not use)
a. With standard wiring
Pin layout of MB 620T FS:
Connecting
Assignment
terminals
1
I0.A
2
I1.A
3
I2.A (control voltage ON, CVO.A)
4
I3.A
5
I0.B
6
I1.B
7
I2.B (control voltage ON, CVO.B)
8
I3.B
9
Power supply for channel A (-TEST.A)
10
Power supply for channel B (-TEST.B)
a. With standard wiring
Danger
Please note that the MB 620T is powered by +24 V NC.
For the entire HSCI system, the +24 V NC power supply voltage is required
to be safely separated voltage. It must also be safely separated from the
+24 V PLC!
a
a
a
HEIDENHAIN Technical Manual MANUALplus 620