Parameter
MP number
iTNC MP number
unit
103501
value
103502
MP4110 / 4120
CfgPlcFastInput
Configuration of fast PLC inputs;
Specifies the numbers, operands and edge detection. Keep in mind that the time between two edges
must be longer than the time from 'MP_CfgCycleTimes/ipoCycle'.
number
103701
MP4130
significance
103702
MP4131
operand
103703
(optional parameter)
440
Function and input
Unit of measure
Format:
Selection menu
Input:
SECONDS:
Input in seconds [s]
PLC_CYCLES:
Input in number of PLC cycles
Default:
SECONDS
Default value for PLC timers/counters
Format:
List [1 to 100]
Input:
0 to 1 000 000 [s or PLC cycles]
Default:
0 [s or PLC cycles]
Numbers of fast PLC inputs
Format:
List [0 to 4]
Input:
0 to 9999
Default:
0
Activation criteria for fast PLC inputs
Format:
List [0 to 4] with selection menu
Input:
lowActive:
Activate at LOW level
highActive:
Activate at HIGH level
allEdges:
Activate at both levels
disabled:
Switched off
PLC operand for fast PLC inputs
Name or number of the operand that is set
through the fast PLC input.
Format:
List [0 to 4]
Input:
String, max. 24 characters