Download Print this page

HEIDENHAIN MANUALplus 620 Technical Manual page 862

Hide thumbs Also See for MANUALplus 620:

Advertisement

6.16.12 Peculiarities in weakened-field operation with CC 61xx and CC 424
Reduction of the
magnetization
current
MP_iCtrlMotVRedFact
862
Settings in the configuration editor
Axes
ParameterSets
[Key name of the parameter set]
CfgCurrentControl
iCtrlMotVRedFact
Some of the asynchronous spindle motors require a high magnetizing current
at low speeds (n < n
field weakening
lead to thermal motor problems at the rpm for field weakening n
there is no load.
The nominal voltage (and so also the nominal magnetization current) at the
rpm for field weakening n
MP_iCtrlMotVRedFact. The entered reduction results in a nominal voltage
curve as shown in the figure below. The maximum nominal voltage is reached
when n = 3 · n
field weakening
% (MP_iCtrlMotVRedFact = 60).
If a load is placed on the drive, then the nominal voltage is increased again
automatically in order to improve the dynamics.
U
nominal
). This magnetizing current can, however,
when there is no load can be reduced with
FW
. The nominal voltage can be reduced by max. 60
n
FW
HEIDENHAIN Technical Manual MANUALplus 620
MP number
401005
when
FW
n
3 · n
FW

Advertisement