6.10.5 Compensation of static friction
January 2012
Settings in the configuration editor
Axes
ParameterSets
[Key name of the parameter set]
CfgSpeedControl
vCtrlIntTime
The parameter object CfgSpeedControl is not required for:
Virtual axes (MP_axisMode=Virtual)
Axes that are for display only (MP_axisMode=Display)
Analog axes (MP_axisHw=Analog)
In machines with a great deal of static friction (stiction), a high integral-action
component can accumulate over time if there is a position error at standstill.
This can result in a jump in position when the axis begins moving. In such
cases you can limit the integral-action component of the speed controller in
MP_vCtrlIntTime:
Enter a limit in MP_vCtrlIntTime. Realistic input values: 0.1 to 2.0
MP_vCtrlIntTime
Limit of integral factor of the speed controller
Available from NCK software version: 597 110-01.
Format:
Numerical value
Input:
0.000 000 000 to 30 [s]
Default:
0 [s]
Access:
LEVEL3
Reaction:
RUN
6.10 Axis Error Compensation
MP number
400903