6.11 Machine Kinematics (As of NC Software 548328-03)
Module 9098 Find active kinematics configuration
The PLC uses Module 9098 to find the active kinematics configuration. Both
the index from CfgKinList as well as the key name of the kinematic model can
be interrogated.
Constraints:
The module is not executable in the cyclic PLC program.
Call:
PS
B/W/D/K <>String number for key name of the kinematic model>
0...15: String number for key name
(the index from CfgKinList is also acquired)
–1: Only find index from CfgKinList; do not acquire the name
CM
9098
PL
B/W/D
<>Index from CfgKinList>
–1: Index could not be acquired
Error recognition:
Marker
Value
M4203 or
0
NN_GenApiModule
1
Error
W1022 or
2
NN_GenApiModule
ErrorCode
20
30
58
Meaning
Kinematic configuration was selected
Error code in
NN_GenApiModuleErrorCode
Invalid parameter programmed for string
number
Module was not called in a spawn or
submit job
Configuration datum CfgKinList or
CfgActivateKinem is not defined, or the
entry from CfgActivateKinem was not
found in CfgKinList
No NC channel configured, or more than
one configured