Parameter
MP number
iTNC MP number
DefGlobG147SCI
602013
DefGlobG147SCK
602014
DefGlobOverMeasI
602015
DefGlobOverMeasK
602016
DefaultM3M4
602017
January 2012
Function and input
Global safety clearance G147 in the plane
Specify here the default setting for the global safety
clearance in the plane for the START unit (SCI
parameter).
Format:
Numerical value
Input:
–999999999 to 999999999 [mm]
Max. 9 decimal places
Default:
2 [mm]
Global safety clearance G147 in infeed direction
Specify here the default setting for the global safety
clearance in infeed direction for the START unit
(SCK parameter).
Format:
Numerical value
Input:
–999999999 to 999999999 [mm]
Max. 9 decimal places
Default:
2 [mm]
Global oversize in X direction
Specify here the default setting for the global safety
clearance in X direction for the START unit (I
parameter).
Format:
Numerical value
Input:
–999999999 to 999999999 [mm]
Max. 9 decimal places
Default:
0.5 [mm]
Global oversize in Z direction
Specify here the default setting for the global safety
clearance in Z direction for the START unit (K
parameter).
Format:
Numerical value
Input:
–999999999 to 999999999 [mm]
Max. 9 decimal places
Default:
0.2 [mm]
Rotational direction for new units
Default for the spindle "direction of rotation MD" in
the "Tool" tab when creating/opening a new unit.
Format:
Selection menu
Input:
M3
M4
Default:
M3
4.10 List of Machine Parameters
Reaction/
Page
Access
RUN
1419
LEVEL1
RUN
1419
LEVEL1
RUN
1419
LEVEL1
RUN
1419
LEVEL1
RUN
1419
LEVEL1
597