Download Print this page

HEIDENHAIN MANUALplus 620 Technical Manual page 234

Hide thumbs Also See for MANUALplus 620:

Advertisement

X106 – Safety:
Single-/dual-
channel PLC
outputs (on the
front)
234
Connections on the front of the UxC 11x FS:
8 dual-channel PLC outputs:
O0.A to O7.A
O0.B to O7.B
8 single-channel PLC outputs:
O8.A to O15.A
Terminal
Signal designation Assignm. / Function
1a
O4.B
2a
O5.B
3a
O6.B
4a
O7.B
5a
O4.A
6a
O5.A
7a
O6.A
8a
O7.A
9a
O12.A
10a
O13.A
11a
O14.A
12a
O15.A
1b
O0.B
2b
O1.B
3b
O2.B
4b
O3.B
5b
O0.A
6b
O1.A
7b
O2.A
8b
O3.A
9b
O8.A
10b
O9.A
11b
O10.A
12b
O11.A
Note
Each output of the UxC 11x (FS) can be loaded with a maximum current of
150 mA.
Note
If the integrated PLC outputs do not suffice for your application, you can
connect up to 7 additional external PL 61xx expansion PLs to the
UxC 111FS via the HSCI interface.
24 V outputs, can be switched off via ter-
minal X104.2a (+24 V.B)
24 V outputs, can be switched off via ter-
minal X104.1a (+24 V.A)
24 V outputs, can be switched off via ter-
minal X104.3a (+24 V.C)
24 V outputs, can be switched off via ter-
minal X104.2a (+24 V.B)
24 V outputs, can be switched off via ter-
minal X104.1a (+24 V.A)
24 V outputs, can be switched off via ter-
minal X104.3a (+24 V.C)
HEIDENHAIN Technical Manual MANUALplus 620

Advertisement

loading