Parameter
MP number
iTNC MP number
override100Ratio
103411
overrideDelta
103407
(optional parameter)
overrideIntegDelta
103408
(optional parameter)
438
Function and input
Compensation for differing adjustment of the
override potentiometers
Reserved for HEIDENHAIN, do not make any
entries in this parameters on your own.
Format:
Numerical value
Input:
0.5 to 1.0
Default:
0.6275
Compensation for thermal noise in override
potentiometers
Format:
Numerical value
Input:
0.0001 to 0.1
Default:
0.0005
Compensation for thermal noise in override
potentiometers
Format:
Numerical value
Input:
0.0001 to 1.0
Default:
0.025