X9 – Safety: Safety-
related PLC inputs/
outputs
Terminal
NEW signal
design.
1a
24 V.A
2a
–STOS.A.G
a
3a
–STO.A.G
4a
TEST.A
5a
O0.A
6a
O1.A
7a
–ES.A
8a
I0.A
9a
I1.A
10a
I2.A
11a
I3.A
12a
I4.A
13a
I5.A
14a
–PF.PS.AC
15a
–PF.PS.DC
1b
24 V.B
2b
0 V
3b
Do not assign
4b
TEST.B
5b
O0.B
6b
O1.B
7b
–ES.B
224
Pin layout of PLB 620x FS:
The triggering outputs at X9 each supply up to 150 mA of output current. The
only exceptions are the two outputs –STOS.A.G and –STO.A.G with max. 2 A
of output current. In the event of an overload or short circuit and as a conse-
quence of excessive temperature, the individual PLC outputs switch off auto-
matically. Then the outputs will try to switch on again cyclically.
Two outputs and six inputs are available at X9 of a PLB 620x FS for free use.
Further PLC inputs/outputs must be realized by means of I/O modules.
OLD connector/signal design.
(MC 42xC)
X44
a
–SHS1A (safe stop of spindle)
X41.32
–SH1A (safe stop)
X41.34 / O33
T.2 / X165.2
–NE1 / X42.4 / I3
Acknowledgment: "Control is
ready"
–PF.PS.AC (signal on X69)
–PF.PS.ZK (signal on X69)
X44
T.1 / X165.1
–NE2 / X42.33 / I32
"Drive enabling"
Assignm. / Function
24 V supply of the outputs
MC.RDY, O.0 to O.1
24 V output: (spindle safe torque
off)
24 V output: (safe torque off)
Control-is-ready signal
24 V output for emergency stop
chain
24 V outputs (high-side driver)
24 V input
Emergency Stop input 1
24 V inputs (PLC)
24 V outputs for powerfail
24 V supply of the outputs O.0 to
O.1
0 V PLC for all I/Os
24 V outputs (high-side driver)
24 V output for emergency stop
chain
24 V outputs (high-side driver)
24 V input
Emergency Stop input 2
HEIDENHAIN Technical Manual MANUALplus 620

Advertisement

loading