4.9 Switching Parameter Sets
398
You can store multiple parameter sets for an axis or spindle in the
configuration editor.
Switching of parameter sets can be necessary, for example,
if other parameters are necessary for a motor for different load or shaft
speed ranges.
if control is to be dependent on the load during C-axis operation.
if a wye/delta connection switchover is carried out for the spindle motor.
If there is more than one parameter set for one axis, use Module 9434 to
select the desired parameter set and Module 9435 to check the currently
active parameter set.
Danger
Ensure that switching the machine parameters does not result in the
machine entering an uncontrolled state.
HEIDENHAIN recommends:
When switching the parameters, the affected drive should be switched off,
or at least brought to a standstill! Controller and filter parameters should
only be switched while a drive is at a standstill, and not during machining,
since the switchover could affect the workpiece surface.
Incorrect or non-optimized parameter input values can lead to faulty
machine performance.
HEIDENHAIN does not accept any responsibility for direct or indirect
damage or injury caused to property or persons through improper use or
incorrect parameterization of the machine.