X79: Unit bus
204
Connection:
40-pin ribbon
Assignment
connector
1a to 3b
0 V *1
4a
+24 V *1
4b
+24 V *1
5a
+15 V *1
5b
+24 V *1
6a
+15 V *1
6b
+15 V *1
7a to 8b
Do not assign
9a
Reserved (SDA)
9b
Do not assign
10a
Reserved (SCL)
10b
ERR.TEMP
11a
PF.PS
11b
0 V
12a
RES.PS
12b
0 V
13a
PWR.OFF
13b
0 V
14a
5 V FS (spindle
enable)
14b
0 V
15a
5 V FA (axis
enable)
15b to 16b
0 V
17a and 17b
–15 V
18a and 18b
+15 V
19a to 20b
+5 V
Danger
The interface complies with the requirements of EN 61800-5-1 for low volt-
age electrical separation (except for 1a to 6b).
These voltages must
not be linked with other voltages
(only basic insulation)!