Machine parameters in the CfgOemPath configuration object:
MP_dispLangText
Display language-sensitive names in the configuration editor?
Available from NCK software version: 597 110-01.
Format:
Selection menu
Selection:
TRUE
Language-sensitive names are displayed.
FALSE
System names are displayed.
Default:
TRUE
Access:
LEVEL3
Reaction:
NOTHING
Note
All files can be managed with PLCdesignNT, as well as transmitted to the
control. PLCdesignNT is available from HEIDENHAIN.
Settings in the configuration editor
CfgConfigDataFiles
dataFiles
The file types and default settings of the PLC parameters are defined in the
file plc_oem.cfg. The file can be named anything you want. The path of the
file is to be entered in the dataFiles list of the CfgConfigDataFiles entity,
which appears after pressing the CONFIG FILE LISTS soft key. The file types
CfgOemBool, CfgOemInt, CfgOemPosition and CfgPlcTimer can be used
in the parameter layout.
In order to change the code number for PLC parameters (5555), the file
plc_attr.cfg must be modified.
Example:
In order to display the PLC parameters, the new code number 123456 is to be
valid in addition to the previous code number 5555.
Add the following entity to the plc_attr.cfg file:
CfgPassword (
key:="123456",
funcList:= [
"CONFIGEDIT-PLC_Parameter",
"CONFIG-LEVEL1"
] )
4.3 User Parameters
MP number
106303
371