Download Print this page

HEIDENHAIN MANUALplus 620 Technical Manual page 20

Hide thumbs Also See for MANUALplus 620:

Advertisement

20
Checking and saving new machine parameters:
After having installed the new NC software and rebooted the control, you
must check and confirm the new machine parameters. The code number
dialog box appears on the screen:
Enter the MP code number 95148 and confirm your entry with the ENT key.
Press the UPDATE RULES soft key.
Check the listed update rules. Each entry in the list stands for a new
parameter that was added to the system by the update.
Exit the UPDATE RULES with the END soft key.
Press the CONFIG DATA soft key.
Before the configuration editor opens, an informational window is displayed,
reporting the removal of the CfgRestorePosition machine parameter. Press
the NEXT soft key.
All new machine parameters are marked with a red exclamation point in the
configuration editor. The control indicates if certain machine parameters are
faulty. Please ignore these messages for the time being.
Important step: Press the SAVE soft key
The Configuration data changed dialog box opens. Press the SAVE soft key
again. The new machine parameters are now automatically saved in the
*.cfg files.
Press the END soft key and exit the Machine Parameter operating mode by
pressing the END soft key again.
The control then continues booting.
Note
The definition file of the symbolic programming interface API 3.0 has been
expanded. The step described below must be taken for the PLC program
to be compiled successfully after the update.
HEIDENHAIN Technical Manual MANUALplus 620

Advertisement

loading