Parameter
MP number
iTNC MP number
Columns
Specifies the column names for all columns of all tables
[Key name = Name of the column]
As key name, enter the name of the table column.
If the column is to be used only in a certain table, you must enter a unique key name. The column
name must be preceded by the table type (i.e. the table extension) followed by a period:
[Table extension].[Column name]
E.g. MOT.Mmax, TCH.T, etc.
If a column is used in two or more tables, a simple key name is enough, for example NAME (without
a period).
CfgColumnDescription
Definition of a table column, column description
width
105601
466
Function and input
Column width
Defines the width for the column made in the
table file. At least one character for the column
name and one character for spacing from the next
column.
Format:
Numerical value
Input:
2 to 50
(column width of max. 50
characters)
Default:
2
HEIDENHAIN Technical Manual MANUALplus 620
Behavior
Page
Access
SW vers.
PLC/Pgm
1600
run is
locked
LEVEL3