3.18 Configuring the PLC Inputs/Outputs with IOconfig
238
The PC program IOconfig is used to configure the PLB 6xxx input/output mod-
ules connected via the HSCI network. The program has previously been used
to describe a PROFIBUS system, and now it also includes the HSCI system.
If desired, IOconfig creates the configuration file (IOC file) and symbol defini-
tion file (DEF file) for the control or the PLC program.
The following properties (and others) of the HSCI system are defined with
IOconfig:
Position of all input/output modules in the HSCI system (PL 6xxx with
associated PLD-H and PLA-H modules, MB 6xx and UEC 11x)
Definition of all I/Os freely available to the OEM on PLD-Hs, PLA-Hs, MB 6xx
and UEC 11x.
Assignment of symbolic names, PLC operand addresses and other
properties of the individual terminals (I/Os)
For more information about using IOconfig and configuring the HSCI I/Os,
please refer to the program's online help.