Data Readouts - Danfoss VLT AQUA Drive FC 200 Programming Manual

Hide thumbs Also See for VLT AQUA Drive FC 200:
Table of Contents

Advertisement

Parameter Lists

4.1.15 Data Readouts 16-**

Par.
Parameter description
No. #
16-0* General Status
16-00
Control Word
16-01
Reference [Unit]
4
4
16-02
Reference [%]
16-03
Status Word
16-05
Main Actual Value [%]
16-09
Custom Readout
16-1* Motor Status
16-10
Power [kW]
16-11
Power [hp]
16-12
Motor voltage
16-13
Frequency
16-14
Motor current
16-15
Frequency [%]
16-16
Torque [Nm]
16-17
Speed [RPM]
16-18
Motor Thermal
16-20
Motor Angle
16-22
Torque [%]
16-3* Drive Status
16-30
DC Link Voltage
16-32
Brake Energy /s
16-33
Brake Energy /2 min
16-34
Heatsink Temp.
16-35
Inverter Thermal
16-36
Inv. Nom. Current
16-37
Inv. Max. Current
16-38
SL Controller State
16-39
Control Card Temp.
16-40
Logging Buffer Full
16-49
Current Fault Source
16-5* Ref. & Feedb.
16-50
External Reference
16-52
Feedback [Unit]
16-53
Digi Pot Reference
16-54
Feedback 1 [Unit]
16-55
Feedback 2 [Unit]
16-56
Feedback 3 [Unit]
16-58
PID Output [%]
16-59
Adjusted Setpoint
16-6* Inputs & Outputs
16-60
Digital Input
16-61
Terminal 53 Switch Setting
16-62
Analog Input 53
16-63
Terminal 54 Switch Setting
16-64
Analog Input 54
16-65
Analog Output 42 [mA]
16-66
Digital Output [bin]
16-67
Pulse Input #29 [Hz]
16-68
Pulse Input #33 [Hz]
16-69
Pulse Output #27 [Hz]
16-70
Pulse Output #29 [Hz]
16-71
Relay Output [bin]
16-72
Counter A
16-73
Counter B
16-75
Analog In X30/11
16-76
Analog In X30/12
4-14
®
VLT
AQUA Drive Programming Guide
Default value
0 N/A
0 ReferenceFeedbackUnit
0 %
0 N/A
0 %
0 CustomReadoutUnit
0 kW
0 hp
0 V
0 Hz
0 A
0 %
0 Nm
0 RPM
0 %
0 N/A
0 %
0 V
0 kW
0 kW
0 °C
0 %
ExpressionLimit
ExpressionLimit
0 N/A
0 °C
[0] No
0 N/A
0 N/A
0 ProcessCtrlUnit
0 N/A
0 ProcessCtrlUnit
0 ProcessCtrlUnit
0 ProcessCtrlUnit
0 %
0 ProcessCtrlUnit
0 N/A
[0] Current
0 N/A
[0] Current
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
®
MG20O622 - VLT
is a registered Danfoss trademark
4-set-up
Change
Conver-
during
sion index
operation
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
100
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
100
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
Type
0
V2
-3
Int32
-1
Int16
0
V2
-2
N2
-2
Int32
1
Int32
-2
Int32
-1
Uint16
-1
Uint16
-2
Int32
-2
N2
-1
Int32
67
Int32
0
Uint8
0
Uint16
0
Int16
0
Uint16
0
Uint32
0
Uint32
Uint8
0
Uint8
-2
Uint32
-2
Uint32
0
Uint8
Uint8
-
Uint8
0
Uint8
-1
Int16
-3
Int32
-2
Int16
-3
Int32
-3
Int32
-3
Int32
-1
Int16
-3
Int32
0
Uint16
-
Uint8
-3
Int32
-
Uint8
-3
Int32
-3
Int16
0
Int16
0
Int32
0
Int32
0
Int32
0
Int32
0
Uint16
0
Int32
0
Int32
-3
Int32
-3
Int32

Advertisement

Table of Contents
loading

Table of Contents