Parameter Description
0-10 Active Set-up
Option:
3
3
[0] Factory
setup
[1] Set-up 1
[2] Set-up 2
[3] Set-up 3
[4] Set-up 4
[9] Multi setup Is used for remote selection of set-ups using
0-11 Programming Set-up
Option:
[0] Factory
setup
[1] Set-up 1
[2] Set-up 2
[3] Set-up 3
[4] Set-up 4
[9] Active Set-
up
3-4
VLT
Function:
Select the set-up in which the adjustable
frequency drive is to operate.
Use 0-51 Set-up Copy to copy a set-up to one or
all other set-ups. To avoid conflicting settings of
the same parameter within two different set-
ups, link the set-ups together using 0-12 This
Set-up Linked to. Stop the adjustable frequency
drive before switching between set-ups, where
parameters marked 'not changeable during
operation' have different values.
Parameters which are 'not changeable during
operation' are marked FALSE in 4 Parameter
Lists.
Cannot be changed. It contains the Danfoss
data set, and can be used as a data source
when returning the other set-ups to a known
state.
[1] Set-up 1 to [4] Set-up 4 are the four
parameter set-ups within which all parameters
can be programmed.
digital inputs and the serial communication
port. This set-up uses the settings from 0-12 This
Set-up Linked to.
Function:
Select the set-up to be edited (i.e.,
programmed) during operation: either the
active set-up or one of the inactive set-ups.
The set-up number to be edited is displayed in
the LCP in parentheses.
Cannot be edited, but it is useful as a data
source for returning the other set-ups to a
known state.
[1] Set-up 1 to [4] Set-up 4 can be edited freely
during operation, independently of the active
set-up.
(i.e., the set-up in which the adjustable
frequency drive is operating) can also be
edited during operation. Editing parameters in
the chosen set-up would normally be done
MG20O622 - VLT
®
AQUA Drive Programming Guide
0-11 Programming Set-up
Option:
0-12 This Set-up Linked to
Option:
®
is a registered Danfoss trademark
Function:
from the LCP, but it is also possible from any
of the serial communication ports.
Function:
This parameter only needs to be programmed if
changing set-ups is required while the motor is
running. It ensures that parameters that are 'not
changeable during operation' have the same
setting in all relevant set-ups.
To enable conflict-free changes from one set-up
to another while the adjustable frequency drive is
running, link set-ups containing parameters that
are not changeable during operation. The link
will ensure the proper synchronization of the 'not
changeable during operation' parameter values
when moving from one set-up to another during
operation. 'Not changeable during operation'
parameters can be identified by the label FALSE
in the parameter lists in 4 Parameter Lists.
The 0-12 This Set-up Linked to feature is used
when Multi set-up in 0-10 Active Set-up is
selected. Multi set-up can be used to move from
one set-up to another during operation (i.e.,
while the motor is running).
Example:
Use Multi set-up to shift from Set-up 1 to Set-up
2 while the motor is running. Program
parameters in Set-up 1 first, then ensure that Set-
up 1 and Set-up 2 are synchronized (or 'linked').
Synchronization can be performed in two ways:
1. Change the edit set-up to [2] Set-up 2 in
0-11 Programming Set-up and set 0-12 This Set-up
Linked to to [1] Set-up 1. This will start the linking
(synchronizing) process.
Figure 3.1
OR
2. While still in Set-up 1, using 0-50 LCP Copy,
copy Set-up 1 to Set-up 2. Then set 0-12 This Set-
up Linked to to [2] Set-up 2. This will start the
linking process.