Parameters 35-** Sensor Input Option - Danfoss VLT AQUA Drive FC 200 Programming Manual

Hide thumbs Also See for VLT AQUA Drive FC 200:
Table of Contents

Advertisement

Parameter Description

3.27 Parameters 35-** Sensor Input Option

3.27.1 35-0* Temp. Input Mode (MCB 114)
3
3
35-00 Term. X48/4 Temp. Unit
Select the unit to be used with temperature input X48/4 settings
and readouts:
Option:
[60]
[160]
35-01 Term. X48/4 Input Type
View the temperature sensor type detected at input X48/4:
Option:
[0]
[1]
[3]
[5]
[7]
35-02 Term. X48/7 Temp. Unit
Select the unit to be used with temperature input X48/7 settings
and readouts:
Option:
[60]
[160]
35-03 Term. X48/7 Input Type
View the temperature sensor type detected at input X48/7:
Option:
[0]
[1]
[3]
[5]
[7]
35-04 Term. X48/10 Temp. Unit
Select the unit to be used with temperature input X48/10
settings and readouts:
Option:
[60]
[160]
35-05 Term. X48/10 Input Type
View the temperature sensor type detected at input X48/10:
Option:
[0]
[1]
[3]
[5]
[7]
3-168
Function:
°C
°F
Function:
Not Connected
PT100 2-wire
PT1000 2-wire
PT100 3-wire
PT1000 3-wire
Function:
°C
°F
Function:
Not Connected
PT100 2-wire
PT1000 2-wire
PT100 3-wire
PT1000 3-wire
Function:
°C
°F
Function:
Not Connected
PT100 2-wire
PT1000 2-wire
PT100 3-wire
PT1000 3-wire
MG20O622 - VLT
®
VLT
AQUA Drive Programming Guide
35-06 Temperature Sensor Alarm Function
Select the alarm function:
Option:
[0]
[2]
[5]
3.27.2 35-1* Temp. Input X48/4 (MCB 114)
35-14 Term. X48/4 Filter Time Constant
Range:
0.001 s
*
35-15 Term. X48/4 Temp. Monitor
This parameter gives the possibility of enabling or disabling the
temperature monitor for terminal X48/4. The temperature limits
can be set in 35-16 Term. X48/4 Low Temp. Limit and 35-17 Term.
X48/4 High Temp. Limit.
Option:
[0]
[1]
35-16 Term. X48/4 Low Temp. Limit
Range:
Size related
35-17 Term. X48/4 High Temp. Limit
Range:
Size related
3.27.3 35-2* Temp. Input X48/7 (MCB 114)
35-24 Term. X48/7 Filter Time Constant
Range:
0.001 s
*
®
is a registered Danfoss trademark
Off
Stop
Stop and trip
Function:
[0.001 - 10
Enter the filter time constant. This is a
s]
first-order digital low pass filter time
constant for suppressing electrical noise
in terminal X48/4. A high time constant
value improves dampening but also
increases the time delay through the
filter.
Disabled
Enabled
[ -50 - par. 35-17 ]
*
[ par. 35-16 - 204 ]
*
Function:
[0.001 - 10
Enter the filter time constant. This is a
s]
first-order digital low pass filter time
constant for suppressing electrical noise
in terminal X48/7. A high time constant
value improves dampening but also
increases the time delay through the
filter.
Function:
Function:
Function:
Function: