Parameter Lists
4.1.20 Timed Actions 23-**
Par.
Parameter description
No. #
23-0* Timed Actions
23-00 ON Time
23-01 ON Action
23-02 OFF Time
23-03 OFF Action
23-04 Occurrence
23-1* Maintenance
23-10 Maintenance Item
23-11 Maintenance Action
23-12 Maintenance Time Base
23-13 Maintenance Time Interval
23-14 Maintenance Date and Time
23-1* Maintenance Reset
23-15 Reset Maintenance Word
23-16 Maintenance Text
23-5* Energy Log
23-50 Energy Log Resolution
23-51 Period Start
23-53 Energy Log
23-54 Reset Energy Log
23-6* Trending
23-60 Trend Variable
23-61 Continuous Bin Data
23-62 Timed Bin Data
23-63 Timed Period Start
23-64 Timed Period Stop
23-65 Minimum Bin Value
23-66 Reset Continuous Bin Data
23-67 Reset Timed Bin Data
23-8* Payback Counter
23-80 Power Reference Factor
23-81 Energy Cost
23-82 Investment
23-83 Energy Savings
23-84 Cost Savings
Table 4.21
4.1.21 24-** Application Functions 2
Par.
Parameter description
No. #
24-1* Drive Bypass
24-10
Drive Bypass Function
24-11
Drive Bypass Delay Time
Table 4.22
®
VLT
AQUA Drive Programming Guide
Default value
ExpressionLimit
[0] Disabled
ExpressionLimit
[0] Disabled
[0] All days
[1] Motor bearings
[1] Lubricate
[0] Disabled
1 h
ExpressionLimit
[0] Do not reset
0 N/A
[5] Last 24 Hours
ExpressionLimit
0 N/A
[0] Do not reset
[0] Power [kW]
0 N/A
0 N/A
ExpressionLimit
ExpressionLimit
ExpressionLimit
[0] Do not reset
[0] Do not reset
100 %
1 N/A
0 N/A
0 kWh
0 N/A
Default value
[0] Disabled
0 s
®
MG20O622 - VLT
is a registered Danfoss trademark
4-set-up
Change
Conver-
during
sion index
operation
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
All set-ups
TRUE
1 set-up
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
2 set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
4-set-up
Change
during
operation
2 set-ups
TRUE
2 set-ups
TRUE
Type
TimeOfDay-
0
WoDate
4
-
Uint8
TimeOfDay-
0
WoDate
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
74
Uint32
0
TimeOfDay
-
Uint8
0
VisStr[20]
-
Uint8
0
TimeOfDay
0
Uint32
-
Uint8
-
Uint8
0
Uint32
0
Uint32
0
TimeOfDay
0
TimeOfDay
0
Uint8
-
Uint8
-
Uint8
0
Uint8
-2
Uint32
0
Uint32
75
Int32
0
Int32
Conver-
Type
sion index
-
Uint8
0
Uint16
4-19
4

Advertisement

Table of Contents
loading

Table of Contents