Parameter Description
13-40 Logic Rule Boolean 1
Array [6]
Option:
Function:
[6]
Current Limit
See parameter group 5-3* for further
description.
[7]
Out of current
See parameter group 5-3* for further
range
description.
[8]
Below I low
See parameter group 5-3* for further
description.
[9]
Above I high
See parameter group 5-3* for further
description.
[10]
Out of speed range
[11]
Below speed low
See parameter group 5-3* for further
description.
[12]
Above speed high
See parameter group 5-3* for further
description.
[13]
Out of feedb.
See parameter group 5-3* for further
range
description.
[14]
Below feedb. low
See parameter group 5-3* for further
description.
[15]
Above feedb. high
See parameter group 5-3* for further
description.
[16]
Thermal warning
See parameter group 5-3* for further
description.
[17]
Mains out of range See parameter group 5-3* for further
description.
[18]
Reverse
See parameter group 5-3* for further
description.
[19]
Warning
See parameter group 5-3* for further
description.
[20]
Alarm (trip)
See parameter group 5-3* for further
description.
[21]
Alarm (trip lock)
See parameter group 5-3* for further
description.
[22]
Comparator 0
Use the result of comparator 0 in the
logic rule.
[23]
Comparator 1
Use the result of comparator 1 in the
logic rule.
[24]
Comparator 2
Use the result of comparator 2 in the
logic rule.
[25]
Comparator 3
Use the result of comparator 3 in the
logic rule.
[26]
Logic rule 0
Use the result of logic rule 0 in the
logic rule.
[27]
Logic rule 1
Use the result of logic rule 1 in the
logic rule.
®
VLT
AQUA Drive Programming Guide
13-40 Logic Rule Boolean 1
Array [6]
Option:
[28]
[29]
[30]
[31]
[32]
[33]
[34]
[35]
[36]
[37]
[38]
[39]
[40]
[41]
[42]
[43]
[44]
®
MG20O622 - VLT
is a registered Danfoss trademark
Function:
Logic rule 2
Use the result of logic rule 2 in the
logic rule.
Logic rule 3
Use the result of logic rule 3 in the
logic rule.
SL Timeout 0
Use the result of timer 0 in the logic
rule.
SL Timeout 1
Use the result of timer 1 in the logic
rule.
SL Timeout 2
Use the result of timer 2 in the logic
rule.
Digital input DI18
Use the value of DI18 in the logic rule
(High = TRUE).
Digital input DI19
Use the value of DI19 in the logic rule
(High = TRUE).
Digital input DI27
Use the value of DI27 in the logic rule
(High = TRUE).
Digital input DI29
Use the value of DI29 in the logic rule
(High = TRUE).
Digital input DI32
Use the value of DI32 in the logic rule
(High = TRUE).
Digital input DI33
Use the value of DI33 in the logic rule
(High = TRUE).
Start command
This logic rule is TRUE if the
adjustable frequency drive is started
by any means (either via digital input,
serial communication bus or other).
Drive stopped
This logic rule is TRUE if the
adjustable frequency drive is stopped
or coasted by any means (either via
digital input, serial communication
bus or other).
Reset Trip
This logic rule is TRUE if the
adjustable frequency drive is tripped
(but not trip-locked) and [Reset] is
pressed.
Auto Reset Trip
This logic rule is TRUE if the
adjustable frequency drive is tripped
(but not trip-locked) and an
automatic reset is issued.
OK key
This logic rule is TRUE if the OK key
on the LCP is pressed.
Reset Key
This logic rule is TRUE if the Reset key
on the LCP is pressed.
3
3
3-79