2.2.7 Quick Menu, Q3 Function Set-ups

The Function Set-up provides quick and easy access to all parameters required for the majority of water and waste water
applications including variable torque, constant torque, pumps, dosing pumps, well pumps, booster pumps, mixer pumps,
aeration blowers and other pump and fan applications. Among other features, it also includes parameters for selecting
which variables to display on the LCP, digital preset speeds, scaling of analog references, closed-loop single zone and multi-
zone applications and specific functions related to water and waste water applications.
The Function Set-up parameters are grouped in the following way:
Q3-10 Clock Settings
0-70 Set Date and Time
0-71 Date Format
0-72 Time Format
0-74 DST/Summertime
0-76 DST/Summertime Start
0-77 DST/Summertime End
Table 2.2
Q3-20 Digital Reference
3-02 Minimum Reference
3-03 Maximum Reference
3-10 Preset Reference
5-13 Terminal 29 Digital Input
5-14 Terminal 32 Digital Input
5-15 Terminal 33 Digital Input
Table 2.3
Q3-30 Feedback Settings
1-00 Configuration Mode
20-12 Reference/Feedb.Unit
3-02 Minimum Reference
3-03 Maximum Reference
6-20 Terminal 54 Low Voltage
6-21 Terminal 54 High Voltage
6-24 Terminal 54 Low Ref/Feedb Value
6-25 Terminal 54 High Ref/Feedb Value
6-00 Live Zero Timeout Time
6-01 Live Zero Timeout Function
Table 2.4
®
VLT
AQUA Drive Programming Guide
Q3-1 General Settings
Q3-11 Display Settings
0-20 Display Line 1.1 Small
0-21 Display Line 1.2 Small
0-22 Display Line 1.3 Small
0-23 Display Line 2 Large
0-24 Display Line 3 Large
0-37 Display Text 1
0-38 Display Text 2
0-39 Display Text 3
Q3-2 Open-loop Settings
Q3-3 Closed-loop Settings
®
MG20O622 - VLT
is a registered Danfoss trademark
Q3-12 Analog Output
6-50 Terminal 42 Output
6-51 Terminal 42 Output Min Scale
6-52 Terminal 42 Output Max Scale Option relay 7 ⇒ 5-40
Q3-21 Analog Reference
3-02 Minimum Reference
3-03 Maximum Reference
6-10 Terminal 53 Low Voltage
6-11 Terminal 53 High Voltage
6-14 Terminal 53 Low Ref/Feedb. Value
6-15 Terminal 53 High Ref/Feedb. Value
Q3-31 PID Settings
20-81 PID Normal/Inverse Control
20-82 PID Start Speed [RPM]
20-21 Setpoint 1
20-93 PID Proportional Gain
20-94 PID Integral Time
Q3-13 Relays
Relay 1 ⇒ 5-40 Function Relay
Relay 2 ⇒ 5-40 Function Relay
Function Relay
Option relay 8 ⇒ 5-40
Function Relay
Option relay 9 ⇒ 5-40
Function Relay
2-7
2
2