How to Program
The Function Set-up provides quick and easy access to all
parameters required for the majority of water and
wastewater applications including variable torque, constant
torque pumps, dosing pumps, well pumps, booster pumps,
mixer pumps, aeration blowers and other pump and fan
applications. Amongst other features, it also includes
parameters for selecting which variables to display on the
LCP, digital preset speeds, scaling of analog references,
closed-loop single zone and multi-zone applications and
specific functions related to water and wastewater
applications.
The Quick Menu parameters can be accessed immediately
unless a password has been created via 0-60 Main Menu
Password, 0-61 Access to Main Menu w/o Password,
0-65 Personal Menu Password or 0-66 Access to Personal
Menu w/o Password.
It is possible to switch directly between Quick Menu mode
and Main Menu mode.
[Main Menu]
is used for programming all parameters.
The Main Menu parameters can be accessed immediately
unless a password has been created via 0-60 Main Menu
Password, 0-61 Access to Main Menu w/o Password,
0-65 Personal Menu Password or 0-66 Access to Personal
Menu w/o Password. For the majority of water and
wastewater applications it is not necessary to access the
Main Menu parameters. The Quick Menu, Quick Setup and
Function Set-ups provide the simplest and quickest access
to the typical required parameters.
It is possible to switch directly between Main Menu mode
and Quick Menu mode.
Parameter shortcut can be carried out by pressing down
[Main Menu] for 3 s. The parameter shortcut allows direct
access to any parameter.
[Alarm Log]
displays an alarm list of the five latest alarms (numbered
A1-A5). To obtain additional details about an alarm, use
the navigation keys to navigate to the alarm number and
press [OK]. Right before entering the alarm mode
information about the condition of the adjustable
frequency drive is provided.
®
VLT
AQUA Drive Programming Guide
Figure 2.5
[Back] goes to the previous step or layer in the navigation
structure.
[Cancel] annuls the latest change or command as long as
the display has not been changed.
[Info] supplies information about a command, parameter,
or function in any display window. [Info] provides detailed
information whenever help is needed.
Exit info mode by pressing either [Info], [Back], or [Cancel].
Navigation Keys
The four navigation keys are used to navigate between the
different choices available in [Quick Menu], [Main Menu]
and [Alarm Log]. Use the keys to move the cursor.
[OK] is used for choosing a parameter marked by the
cursor and for enabling the change of a parameter.
Local Control Key for local control are found at the bottom
of the LCP.
[Hand On] enables control of the adjustable frequency
drive via the LCP. [Hand on] also starts the motor, and it is
now possible to enter the motor speed data using the
navigation keys. The key can be selected as Enable [1] or
Disable [0] via 0-40 [Hand on] Key on LCP
External stop signals activated by means of control signals
or a serial bus will override a "start" command via the LCP.
®