Parameter Description
1-06 Clockwise Direction
This parameter defines the term "Clockwise" corresponding to
the LCP direction arrow. Used for easy change of direction of
3
3
shaft rotation without swapping motor wires.
Option:
[0]
Normal
[1]
Inverse
NOTICE!
This parameter cannot be adjusted while the motor is
running.
3.3.2 1-10 Motor Selection
NOTICE!
This parameter group cannot be adjusted while the motor
is running.
The following parameters are active ('x') depending on the
setting of 1-10 Motor Construction
1-10 Motor Construction
1-00 Configuration Mode
1-03 Torque Characteristics
1-06 Clockwise Direction
1-14 Damping Gain
1-15 Low Speed Filter Time Const.
1-16 High Speed Filter Time Const.
1-17 Voltage filter time const.
1-20 Motor Power [kW]
1-21 Motor Power [HP]
1-22 Motor Voltage
1-23 Motor Frequency
1-24 Motor Current
1-25 Motor Nominal Speed
1-26 Motor Cont. Rated Torque
1-28 Motor Rotation Check
1-29 Automatic Motor Adaptation
(AMA)
1-30 Stator Resistance (Rs)
1-31 Rotor Resistance (Rr)
1-35 Main Reactance (Xh)
3-16
®
VLT
AQUA Drive Programming Guide
Function:
Motor shaft will turn in clockwise
direction when the adjustable
frequency drive is connected U ⇒ U;
V⇒V, and W ⇒ W to motor.
Motor shaft will turn in counter-
clockwise direction when the
adjustable frequency drive is
connected U⇒U; V⇒V, and W⇒ W to
motor.
[0]
[1] PM Motor
Asynchron
non-salient
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
MG20O622 - VLT
1-10 Motor Construction
1-37 d-axis Inductance (Ld)
1-39 Motor Poles
1-40 Back EMF at 1000 RPM
1-50 Motor Magnetization at Zero
Speed
1-51 Min Speed Normal
Magnetizing [RPM]
1-52 Min Speed Normal
Magnetizing [Hz]
1-58 Flystart Test Pulses Current
1-59 Flystart Test Pulses Frequency
1-60 Low Speed Load Compen-
sation
1-61 High Speed Load Compen-
sation
1-62 Slip Compensation
1-63 Slip Compensation Time
Constant
1-64 Resonance Dampening
1-65 Resonance Dampening Time
Constant
1-66 Min. Current at Low Speed
1-70 PM Start Mode
1-71 Start Delay
1-72 Start Function
1-73 Flying Start
1-80 Function at Stop
1-81 Min Speed for Function at
Stop [RPM]
1-82 Min Speed for Function at
Stop [Hz]
1-86 Trip Speed Low [RPM]
1-87 Trip Speed Low [Hz]
1-90 Motor Thermal Protection
1-91 Motor External Fan
1-93 Thermistor Source
2-00 DC Hold/Preheat Current
2-01 DC Brake Current
2-02 DC Braking Time
2-03 DC Brake Cut-in Speed [RPM]
2-04 DC Brake Cut-in Speed [Hz]
2-06 Parking Current
2-07 Parking Time
2-10 Brake Function
2-11 Brake Resistor (ohm)
2-12 Brake Power Limit (kW)
2-13 Brake Power Monitoring
2-15 Brake Check
2-16 AC Brake Max. Current
®
is a registered Danfoss trademark
[0]
[1] PM Motor
Asynchron
non-salient
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x