Parameter Description
3.2.5 0-4* LCP Keypad
Enable, disable and password protect individual keys on
the LCP.
0-40 [Hand on] Key on LCP
Option:
Function:
[0] Disabled
Key disabled avoids accidental usage of the key.
[1] Enabled
[Hand On] key enabled
[2] Password Avoid unauthorized start in hand mode. If
0-40 [Hand on] Key on LCP is included in the My
Personal Menu, then define the password in
0-65 Personal Menu Password. Otherwise, define
the password in 0-60 Main Menu Password.
0-41 [Off] Key on LCP
Option:
Function:
[0] Disabled
Key disabled avoids accidental usage of the key.
[1] Enabled
[Off] key is enabled
[2] Password Avoid unauthorized stop. If 0-41 [Off] Key on LCP is
included in the My Personal Menu, then define
the password in 0-65 Personal Menu Password.
Otherwise, define the password in 0-60 Main Menu
Password.
0-42 [Auto on] Key on LCP
Option:
Function:
[0] Disabled
Key disabled avoids accidental usage of the key.
[1] Enabled
[Auto On] key is enabled
[2] Password Avoid unauthorized start in auto mode. If
0-42 [Auto on] Key on LCP is included in the My
Personal Menu, then define the password in
0-65 Personal Menu Password. Otherwise define the
password in 0-60 Main Menu Password.
0-43 [Reset] Key on LCP
Option:
Function:
[0] Disabled
Key disabled avoids accidental usage
of the key.
[1] Enabled
[Reset] key is enabled
[2] Password
Avoid unauthorized resetting. If
0-43 [Reset] Key on LCP is included in
the 0-25 My Personal Menu, then define
the password in 0-65 Personal Menu
Password. Otherwise, define the
password in 0-60 Main Menu Password.
[3] Enabled without
OFF
[4] Password w/out OFF
[5] Enabled with OFF
®
VLT
AQUA Drive Programming Guide
0-43 [Reset] Key on LCP
Option:
[6] Password with OFF
0-44 [Off/Reset] Key on LCP
Option:
[0] Disabled
[1] Enabled
[2] Password
0-45 [Drive Bypass] Key on LCP
Press [Off] and select [0] Disabled to avoid accidental stop of the
drive. Press [Off] and select [2] Password to avoid unauthorized
bypass of the adjustable frequency drive. If 0-45 [Drive Bypass]
Key on LCP is included in the Quick Menu, then define the
password in 0-65 Personal Menu Password.
Option:
[0]
[1]
[2]
3.2.6 0-5* Copy/Save
Copy parameter settings between set-ups and to/from the
LCP.
0-50 LCP Copy
Option:
[0] No copy
[1] All to LCP
[2] All from
[3] Size indep.
This parameter cannot be adjusted while the motor is
running.
®
MG20O622 - VLT
is a registered Danfoss trademark
Function:
Function:
Key disabled avoids accidental usage of the key.
Disabled
Enabled
Password
Function:
No function
Copies all parameters in all set-ups from the
adjustable frequency drive memory to the LCP
memory. For service purposes, copying all
parameters to the LCP is recommended after
commissioning.
Copies all parameters in all set-ups from the
LCP
LCP memory to the adjustable frequency drive
memory.
Copies only the parameters that are
of LCP
independent of the motor size. The latter
selection can be used to program several
adjustable frequency drives with the same
function without disturbing motor data that are
already set.