Parameter Lists
Par.
Parameter description
No. #
27-10
Cascade Controller
27-11
Number Of Drives
27-12
Number Of Pumps
27-14
Pump Capacity
27-16
Runtime Balancing
4
4
27-17
Motor Starters
27-18
Spin Time for Unused Pumps
27-19
Reset Current Runtime Hours
27-2* Bandwidth Settings
27-20
Normal Operating Range
27-21
Override Limit
27-22
Fixed Speed Only Operating Range
27-23
Staging Delay
27-24
Destaging Delay
27-25
Override Hold Time
27-27
Min Speed Destage Delay
27-3* Staging Speed
27-30
Auto Tune Staging Speeds
27-31
Stage On Speed [RPM]
27-32
Stage On Speed [Hz]
27-33
Stage Off Speed [RPM]
27-34
Stage Off Speed [Hz]
27-4* Staging Settings
27-40
Auto Tune Staging Settings
27-41
Ramp Down Delay
27-42
Ramp Up Delay
27-43
Staging Threshold
27-44
Destaging Threshold
27-45
Staging Speed [RPM]
27-46
Staging Speed [Hz]
27-47
Destaging Speed [RPM]
27-48
Destaging Speed [Hz]
27-5* Alternate Settings
27-50
Automatic Alternation
27-51
Alternation Event
27-52
Alternation Time Interval
27-53
Alternation Timer Value
27-54
Alternation At Time of Day
27-55
Alternation Predefined Time
27-56
Alternate Capacity is <
27-58
Run Next Pump Delay
27-6* Digital Inputs
27-60
Terminal X66/1 Digital Input
27-61
Terminal X66/3 Digital Input
27-62
Terminal X66/5 Digital Input
27-63
Terminal X66/7 Digital Input
27-64
Terminal X66/9 Digital Input
27-65
Terminal X66/11 Digital Input
27-66
Terminal X66/13 Digital Input
27-7* Connections
27-70
Relay
27-9* Readouts
27-91
Cascade Reference
27-92
% Of Total Capacity
27-93
Cascade Option Status
27-94
Cascade System Status
27-95
Advanced Cascade Relay Output [bin]
4-22
®
VLT
AQUA Drive Programming Guide
Default value
ExpressionLimit
ExpressionLimit
ExpressionLimit
100 %
[0] Balanced Priority 1
[0] Direct Online
ExpressionLimit
[0] Do not reset
ExpressionLimit
100 %
ExpressionLimit
15 s
15 s
10 s
ExpressionLimit
[1] Enabled
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
[0] Disabled
10 s
2 s
ExpressionLimit
ExpressionLimit
0 RPM
0 Hz
0 RPM
0 Hz
[0] Disabled
ExpressionLimit
0 min
0 min
[0] Disabled
ExpressionLimit
0 %
0.1 s
[0] No operation
[0] No operation
[0] No operation
[0] No operation
[0] No operation
[0] No operation
[0] No operation
[0] Standard Relay
0 %
0 %
[0] Disabled
0 N/A
0 N/A
®
MG20O622 - VLT
is a registered Danfoss trademark
4-set-up
Change
Conver-
during
sion index
operation
2 set-ups
FALSE
2 set-ups
FALSE
2 set-ups
FALSE
2 set-ups
FALSE
2 set-ups
TRUE
2 set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
2 set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
Type
-
Uint8
0
Uint8
0
Uint8
0
Uint16
-
Uint8
-
Uint8
0
Uint16
-
Uint8
0
Uint8
0
Uint8
0
Uint8
0
Uint16
0
Uint16
0
Uint16
0
Uint16
-
Uint8
67
Uint16
-1
Uint16
67
Uint16
-1
Uint16
-
Uint8
-1
Uint16
-1
Uint16
0
Uint8
0
Uint8
67
Uint16
-1
Uint16
67
Uint16
-1
Uint16
-
Uint8
-
Uint8
70
Uint16
70
Uint16
-
Uint8
TimeOfDay-
0
WoDate
0
Uint8
-1
Uint16
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-1
Int16
0
Uint16
-
Uint8
0
VisStr[25]
0
Uint16