Parameter Description
16-52 Feedback [Unit]
Range:
0
3
3
ProcessCtrlUnit
16-53 Digi Pot Reference
Range:
0
[-200 - 200 ] View the contribution of the digital potenti-
*
16-54 Feedback 1 [Unit]
Range:
0 ProcessCtrlUnit
16-55 Feedback 2 [Unit]
Range:
0
ProcessCtrlUnit
16-56 Feedback 3 [Unit]
Range:
0 ProcessCtrlUnit
3-100
Function:
[-999999.999 -
View value of resulting
999999.999
feedback value after
*
ProcessCtrlUnit]
processing of Feedback 1-3
(see 16-54 Feedback 1 [Unit],
16-55 Feedback 2 [Unit] and
16-56 Feedback 3 [Unit]) in
the feedback manager.
See parameter group 20-0*
Feedback.
The value is limited by
settings in 20-13 Minimum
Reference/Feedb. and
20-14 Maximum Reference/
Feedb.. Units as set in
20-12 Reference/Feedback
Unit.
Function:
ometer to the actual reference.
Function:
[-999999.999 -
View value of
*
999999.999
Feedback 1, see
ProcessCtrlUnit]
parameter group
20-0* Feedback.
Function:
[-999999.999 -
View value of Feedback 2,
999999.999
see parameter group 20-0*
*
ProcessCtrlUnit]
Feedback.
The value is limited by
settings in 20-13 Minimum
Reference/Feedb. and
20-14 Maximum Reference/
Feedb.. Units as set in
20-12 Reference/Feedback
Unit.
Function:
[-999999.999 -
View value of
*
999999.999
Feedback 3, see
ProcessCtrlUnit]
parameter group
20-0* Feedback.
MG20O622 - VLT
®
VLT
AQUA Drive Programming Guide
16-58 PID Output [%]
Range:
0 %
*
16-59 Adjusted Setpoint
Range:
0 ProcessCtrlUnit
3.15.4 16-6* Inputs & Outputs
16-60 Digital Input
Range:
0
[0 -
*
65535 ]
16-61 Terminal 53 Switch Setting
Option:
[0] Current
[1] Voltage
16-62 Analog Input 53
Range:
0
[-20 - 20 ]
*
16-63 Terminal 54 Switch Setting
Option:
[0] Current
[1] Voltage
®
is a registered Danfoss trademark
Function:
[0 - 100 %]
[-999999.999 - 999999.999
*
ProcessCtrlUnit]
Function:
View the signal states from the active digital
inputs. Input 18 corresponds for example to bit
5. '0' = NO signal, '1' = connected signal.
Bit 0
Digital input term. 33
Bit 1
Digital input term. 32
Bit 2
Digital input term. 29
Bit 3
Digital input term. 27
Bit 4
Digital input term. 19
Bit 5
Digital input term. 18
Bit 6
Digital input term. 37
Bit 7
Digital input GP I/O term. X30/2
Bit 8
Digital input GP I/O term. X30/3
Bit 9
Digital input GP I/O term. X30/4
Bit 10-63
Reserved for future terminals
Table 3.21
Function:
View the setting of input terminal 53. Current = 0;
Voltage = 1.
Function:
View the actual value at input 53.
Function:
View the setting of input terminal 54. Current = 0;
Voltage = 1.
Function: