Parameter Description
13-01 Start Event
Option:
[17]
Mains out of range
3
3
[18]
Reverse
[19]
Warning
[20]
Alarm (trip)
[21]
Alarm (trip lock)
[22]
Comparator 0
[23]
Comparator 1
[24]
Comparator 2
[25]
Comparator 3
[26]
Logic rule 0
[27]
Logic rule 1
[28]
Logic rule 2
[29]
Logic rule 3
[33]
Digital input DI18
[34]
Digital input DI19
[35]
Digital input DI27
[36]
Digital input DI29
[37]
Digital input DI32
[38]
Digital input DI33
[39]
Start command
[40]
Drive stopped
3-74
®
VLT
AQUA Drive Programming Guide
Function:
See parameter group 5-3* for further
description.
See parameter group 5-3* for further
description.
See parameter group 5-3* for further
description.
See parameter group 5-3* for further
description.
See parameter group 5-3* for further
description.
Use the result of comparator 0 in the
logic rule.
Use the result of comparator 1 in the
logic rule.
Use the result of comparator 2 in the
logic rule.
Use the result of comparator 3 in the
logic rule.
Use the result of logic rule 0 in the
logic rule.
Use the result of logic rule 1 in the
logic rule.
Use the result of logic rule 2 in the
logic rule.
Use the result of logic rule 3 in the
logic rule.
Use the value of DI18 in the logic
rule (High = TRUE).
Use the value of DI19 in the logic
rule (High = TRUE).
Use the value of DI27 in the logic
rule (High = TRUE).
Use the value of DI29 in the logic
rule (High = TRUE).
Use the value of DI32 in the logic
rule (High = TRUE).
Use the value of DI33 in the logic
rule (High = TRUE).
This event is TRUE if the adjustable
frequency drive is started by any
means (either via digital input, serial
communication bus or other).
This event is TRUE if the adjustable
frequency drive is stopped or coasted
MG20O622 - VLT
13-01 Start Event
Option:
[41]
Reset Trip
[42]
Auto Reset Trip
[43]
OK key
[44]
Reset Key
[45]
Left Key
[46]
Right Key
[47]
Up Key
[48]
Down Key
[50]
Comparator 4
[51]
Comparator 5
[60]
Logic rule 4
[61]
Logic rule 5
[76]
Digital Input x30 2
[77]
Digital Input x30 3
[78]
Digital Input x30 4
[90]
ECB Drive Mode
[91]
ECB Bypass Mode
[92]
ECB Test Mode
[100] Fire Mode
13-02 Stop Event
Option:
[0]
FALSE
[1]
TRUE
[2]
Running
®
is a registered Danfoss trademark
Function:
by any means (either via digital input,
serial communication bus or other).
This event is TRUE if the adjustable
frequency drive is tripped (but not
trip-locked) and [Reset] is pressed.
This event is TRUE if the adjustable
frequency drive is tripped (but not
trip-locked) and an automatic reset is
issued.
This event is TRUE if [OK] is pressed.
This event is TRUE if [Reset] is
pressed.
This event is TRUE if [◄] is pressed.
This event is TRUE if [►] is pressed.
This event is TRUE if [
] is pressed.
This event is TRUE if [
] is pressed.
Use the result of comparator 4 in the
logic rule.
Use the result of comparator 5 in the
logic rule.
Use the result of logic rule 4 in the
logic rule.
Use the result of logic rule 5 in the
logic rule.
Function:
Select the Boolean (TRUE or FALSE)
input to deactivate Smart Logic
Control.
Enters the fixed value of FALSE in the
logic rule.
Enters the fixed value TRUE in the
logic rule.
See parameter group 5-3* for further
description.