Troubleshooting
Bit
Hex
Dec
12
00001000
4096
13
00002000
8192
14
00004000
16384
15
00008000
32768
16
00010000
65536
17
00020000
131072
18
00040000
262144
19
00080000
524288
20
00100000
1048576
21
00200000
2097152
22
00400000
4194304
23
00800000
8388608
24
01000000
16777216
25
02000000
33554432
26
04000000
67108864
27
08000000
134217728
28
10000000
268435456
29
20000000
536870912
30
40000000
1073741824 Safe Stop (A68)
31
80000000
2147483648 Mech. brake low
Table 5.3 Description of Alarm Word, Warning Word and Extended Status Word
The alarm words, warning words and extended status words can be read out via serial bus or optional serial communication
bus for diagnosis. See also 16-94 Ext. Status Word.
®
VLT
AQUA Drive Programming Guide
Alarm Word
Alarm Word 2
Short Circuit (A16)
reserved
Inrush Fault (A33)
reserved
Mains ph. Loss (A4) reserved
AMA Not OK
reserved
Live Zero Error (A2) reserved
Internal Fault (A38) KTY error
Brake Overload
Fans error
(A26)
U phase Loss (A30) ECB error
V phase Loss (A31) reserved
W phase Loss (A32) reserved
Fieldbus Fault (A34) reserved
24 V Supply Low
reserved
(A47)
Mains Failure (A36) reserved
1.8V Supply Low
reserved
(A48)
Brake Resistor (A25) reserved
Brake IGBT (A27)
reserved
Option Change
reserved
(A67)
Drive Initialized
Feedback Fault
(A80)
(A61, A90)
PTC 1 Safe Stop
(A71)
Dangerous Failure
(A63)
(A72)
®
MG20O622 - VLT
is a registered Danfoss trademark
Warning Word
Warning
Word 2
DC Voltage Low (W6)
reserved
DC Voltage High (W5)
Mains ph. Loss (W4)
No Motor (W3)
Live Zero Error (W2)
10 V Low (W1)
KTY Warn
Brake Overload (W26)
Fans Warn
Brake Resistor (W25)
ECB Warn
Brake IGBT (W27)
reserved
Speed Limit (W49)
reserved
Fieldbus Fault (W34)
reserved
24V Supply Low (W47)
reserved
Mains Failure (W36)
reserved
Current Limit (W59)
reserved
Low Temp (W66)
reserved
Voltage Limit (W64)
reserved
Encoder loss (W90)
reserved
Feedback Fault (W61,
W90)
Safe Stop (W68)
PTC 1 Safe
Stop (W71)
Extended Status Word
Extended
Status Word
Braking Max
BrakePower >
BrakePowerLimit
(p212)
Braking
Out of Speed Range
OVC Active
AC Brake
5
Password Timelock
number of allowed
password trials
exceeded - timelock
active
Password Protection
p0-61 =
ALL_NO_ACCESS OR
BUS_NO_ACCESS OR
BUS_READONLY
Reference High
reference > p4-55
Reference Low
reference < p4-54
Local Reference
reference site =
REMOTE -> auto on
pressed & active
Protection Mode
Unused
Unused
Unused
Unused
Unused
Unused
Unused
Unused
Unused
5-5
5