Parameter Lists

4.1.27 Bypass Option 31-**

Par.
Parameter description
No. #
31-00
Bypass Mode
31-01
Bypass Start Time Delay
31-02
Bypass Trip Time Delay
4
4
31-03
Test Mode Activation
31-10
Bypass Status Word
31-11
Bypass Running Hours
31-19
Remote Bypass Activation
Table 4.28

4.1.28 Sensor Input Option 35-**

Par.
Parameter description
No. #
35-0* Temp. Input Mode
35-00
Term. X48/4 Temp. Unit
35-01
Term. X48/4 Input Type
35-02
Term. X48/7 Temp. Unit
35-03
Term. X48/7 Input Type
35-04
Term. X48/10 Temp. Unit
35-05
Term. X48/10 Input Type
35-06
Temperature Sensor Alarm Function
35-1* Temp. Input X48/4
35-14
Term. X48/4 Filter Time Constant
35-15
Term. X48/4 Temp. Monitor
35-16
Term. X48/4 Low Temp. Limit
35-17
Term. X48/4 High Temp. Limit
35-2* Temp. Input X48/7
35-24
Term. X48/7 Filter Time Constant
35-25
Term. X48/7 Temp. Monitor
35-26
Term. X48/7 Low Temp. Limit
35-27
Term. X48/7 High Temp. Limit
35-3* Temp. Input X48/10
35-34
Term. X48/10 Filter Time Constant
35-35
Term. X48/10 Temp. Monitor
35-36
Term. X48/10 Low Temp. Limit
35-37
Term. X48/10 High Temp. Limit
35-4* Analog Input X48/2
35-42
Term. X48/2 Low Current
35-43
Term. X48/2 High Current
35-44
Term. X48/2 Low Ref./Feedb. Value
35-45
Term. X48/2 High Ref./Feedb. Value
35-46
Term. X48/2 Filter Time Constant
35-47
Term. X48/2 Live Zero
Table 4.29
4-24
®
VLT
AQUA Drive Programming Guide
Default value
[0] Drive
30 s
0 s
[0] Disabled
0 N/A
0 h
[0] Disabled
Default value
[60] °C
[0] Not Connected
[60] °C
[0] Not Connected
[60] °C
[0] Not Connected
[5] Stop and trip
0.001 s
[0] Disabled
ExpressionLimit
ExpressionLimit
0.001 s
[0] Disabled
ExpressionLimit
ExpressionLimit
0.001 s
[0] Disabled
ExpressionLimit
ExpressionLimit
4 mA
20 mA
0 N/A
100 N/A
0.001 s
[1] Enabled
®
MG20O622 - VLT
is a registered Danfoss trademark
4-set-up
Change
Conver-
during
sion index
operation
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
FALSE
2 set-ups
TRUE
4-set-up
Change
Conver-
during
sion index
operation
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
Type
-
Uint8
0
Uint16
0
Uint16
-
Uint8
0
V2
74
Uint32
-
Uint8
Type
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-3
Uint16
-
Uint8
0
Int16
0
Int16
-3
Uint16
-
Uint8
0
Int16
0
Int16
-3
Uint16
-
Uint8
0
Int16
0
Int16
-5
Int16
-5
Int16
-3
Int32
-3
Int32
-3
Uint16
-
Uint8