Page 1
MAKING MODERN LIVING POSSIBLE Service Manual ® FC Series, D-Frame ® ® HVAC Drive FC 100 • VLT AQUA Drive FC 200 ® ® Automation Drive FC 300 • VLT Refrigeration Drive FC 103 www.danfoss.com/drives...
Page 57
Troubleshooting Check for loose or missing wiring Check for the following conditions. Ambient temperature too high. It may be necessary to contact your Danfoss supplier or service department. Note the code number for further Motor cable too long. troubleshooting directions.
Unplug more than 3%. the terminal strip and repeat the test. If this test is successful, continue. Remember to check the customer Danfoss calculates line imbalance per an IEC specification. connections. Imbalance = 0.67 X (V – V...
The power card supply should provide between 610 and 750 V DC of power. The Danfoss split bus power supply provides 650 V DC with a capacity of 250 mA. The DC bus supply should provide a low level DC voltage.
Bus bars used in some units are aluminum. Spare part bus bars are copper-plated when available. Copper-plated bus bars are useable for all units. For the latest spare parts list, visit the Danfoss website using the directions below. Spare Parts Lookup Procedure Go to www.danfoss.com/...
Page 134
Danfoss shall not be responsible for any errors in catalogs, brochures or other printed material. Danfoss reserves the right to alter its products at any time without notice, provided that alterations to products already on order shall not require material changes in specifications previously agreed upon by Danfoss and the Purchaser. All trademarks in this material are property of the respective companies.