Parameter Description
3.11.4 10-3* Parameter Access
Parameter group providing access to indexed parameters
and defining programming set-up.
10-30 Array Index
Range:
Function:
0
[0 - 255 ] View array parameters. This parameter is valid
*
only when a DeviceNet serial communication
bus is installed.
10-31 Store Data Values
Option:
Function:
Parameter values changed via DeviceNet are not
automatically stored in non-volatile memory. Use
this parameter to activate a function that stores
parameter values in the EEPROM non-volatile
memory, so changed parameter values will be
retained at power-down.
[0] Off
Deactivates the non-volatile storage function.
[1] Store all
Stores all parameter values from the active set-up
setups
in the non-volatile memory. The selection returns
to [0] Off when all values have been stored.
[2] Store all
Stores all parameter values for all set-ups in the
setups
non-volatile memory. The selection returns to [0]
Off when all parameter values have been stored.
10-32 Devicenet Revision
Range:
Function:
0
[0 - 65535 ] View the DeviceNet revision number.
*
This parameter is used for EDS file
creation.
Size related
[0 - 65535 ]
*
10-33 Store Always
Option: Function:
[0] Off Deactivates non-volatile storage of data.
[1] On Stores parameter data received via DeviceNet in EEProm
non-volatile memory as default.
10-34 DeviceNet Product Code
Range:
Size related
[0 - 65535 ]
*
10-39 Devicenet F Parameters
Array [1,000]
No LCP access
Range:
Function:
0
[0 - 0 ] This parameter is used to configure the adjustable
*
frequency drive via DeviceNet and build the EDS
file.
®
VLT
AQUA Drive Programming Guide
3.11.5 10-5* CANopen
10-50 Process Data Config Write.
Option:
[0]
[302]
[303]
[312]
[341]
[342]
[351]
[352]
[380]
[381]
[411]
[412]
[413]
[414]
[416]
[417]
[590]
[593]
[595]
[597]
[653]
[663]
[673]
[683]
[890]
[891]
[1293]
[1680]
[1682]
[3401]
[3402]
[3403]
[3404]
[3405]
[3406]
[3407]
[3408]
[3409]
Function:
[3410]
10-51 Process Data Config Read.
Option:
[0]
[1472]
[1473]
[1474]
[1500]
[1501]
®
MG20O622 - VLT
is a registered Danfoss trademark
None
*
Minimum Reference
Maximum Reference
Catch up/slow-down value
Ramp 1 Ramp-up Time
Ramp 1 Ramp-down Time
Ramp 2 Ramp-up Time
Ramp 2 Ramp-down Time
Jog Ramp Time
Quick Stop Ramp Time
Motor Speed Low Limit [RPM]
Motor Speed Low Limit [Hz]
Motor Speed High Limit [RPM]
Motor Speed High Limit [Hz]
Torque Limit Motor Mode
Torque Limit Generator Mode
Digital & Relay Bus Control
Pulse Out #27 Bus Control
Pulse Out #29 Bus Control
Pulse Out #X30/6 Bus Control
Terminal 42 Output Bus Control
Terminal X30/8 Bus Control
Terminal X45/1 Bus Control
Terminal X45/3 Bus Control
Bus Jog 1 Speed
Bus Jog 2 Speed
Cable Error Length
Serial communication bus CTW 1
Serial communication bus REF 1
PCD 1 Write to MCO
PCD 2 Write to MCO
PCD 3 Write to MCO
PCD 4 Write to MCO
PCD 5 Write to MCO
PCD 6 Write to MCO
PCD 7 Write to MCO
PCD 8 Write to MCO
PCD 9 Write to MCO
PCD 10 Write to MCO
None
*
VLT Alarm Word
VLT Warning Word
VLT Ext. Status Word
Operating Hours
Running Hours
3
3
Function:
Function: