Parameter Description
0-20 Display Line 1.1 Small
Option:
[1230] Warning
3
3
Parameter
[1500] Operating hours
[1501] Running Hours
[1502] kWh Counter
[1600] Control Word
[1601] Reference [Unit]
[1602] Reference [%]
[1603] Status Word
[1605] Main Actual Value
[%]
[1609] Custom Readout
[1610] Power [kW]
[1611] Power [hp]
[1612] Motor voltage
[1613] Frequency
[1614] Motor current
[1615] Frequency [%]
[1616] Torque [Nm]
[1617] Speed [RPM]
3-6
®
VLT
AQUA Drive Programming Guide
Function:
View the number of running hours of
the adjustable frequency drive.
View the number of running hours of
the motor.
View the line power consumption in
kWh.
View the control word sent from the
adjustable frequency drive via the
serial communication port in hex
code.
Total reference (sum of digital/
analog/preset/bus/freeze ref./catch
up and slow-down) in selected unit.
Total reference (sum of digital/
analog/preset/bus/freeze ref./catch
up and slow-down) in percent.
Present status word
One or more warnings in a Hex code
View the user-defined readouts as
defined in 0-30 Custom Readout Unit,
0-31 Custom Readout Min Value and
0-32 Custom Readout Max Value.
Actual power consumed by the
motor in kW.
Actual power consumed by the
motor in hp.
Voltage supplied to the motor.
Motor frequency, i.e., the output
frequency from the adjustable
frequency drive in Hz.
Phase current of the motor measured
as effective value.
Motor frequency, i.e., the output
frequency from the adjustable
frequency drive in percent.
Present motor load as a percentage
of the rated motor torque.
Speed in RPM (revolutions per
minute), i.e., the motor shaft speed in
closed-loop based on the entered
motor nameplate data, the output
frequency and the load on the
adjustable frequency drive.
MG20O622 - VLT
0-20 Display Line 1.1 Small
Option:
[1618] Motor Thermal
[1622] Torque [%]
[1630] DC Link Voltage
[1632] Brake Energy /s
[1633] Brake Energy /2
min
[1634] Heatsink Temp.
[1635] Inverter Thermal
[1636] Inv. Nom. Current
[1637] Inv. Max. Current
[1638] SL Controller State State of the event executed by the
[1639] Control Card
Temp.
[1650] External Reference Sum of the external reference as a
[1652] Feedback [Unit]
[1653] Digi Pot Reference View the contribution of the digital
[1654] Feedback 1 [Unit]
[1655] Feedback 2 [Unit]
[1656] Feedback 3 [Unit]
[1658] PID Output [%]
®
is a registered Danfoss trademark
Function:
Thermal load on the motor,
calculated by the ETR function. See
also parameter group 1-9* Motor
Temperature.
Shows the actual torque produced, in
percentage.
Intermediate circuit voltage in the
adjustable frequency drive.
Present braking energy transferred to
an external brake resistor.
Stated as an instantaneous value.
Braking energy transferred to an
external brake resistor. The mean
power is calculated continuously for
the most recent 120 seconds.
Present heatsink temperature of the
adjustable frequency drive. The cut-
out limit is 203° F ± 9° F [95°±5°C];
cutting back in occurs at 158° F ±9° F
[70°±5°C].
Percentage load of the inverters
Nominal current of the adjustable
frequency drive.
Maximum current of the adjustable
frequency drive.
control
Temperature of the control card.
percentage, i.e. the sum of analog/
pulse/bus.
Signal value in units from the
programmed digital input(s).
potentiometer to the actual reference
Feedback.
View the value of Feedback 1. See
also parameter group 20-0*.
View the value of Feedback 2. See
also parameter group 20-0*.
View the value of Feedback 3. See
also parameter group 20-0*.
Returns the Drive Closed-loop PID
controller output value in percent.