Installing the S8700 IP Connect

Test the C-LAN Connectivity

1
To test the external IP connections, ping the C-LAN circuit pack and ping a known
computer connected to your network. If everything is configured correctly, the Result
column on the Ping Results screen reads PASS. If it reads ABORT, verify the IP-address
information and check the connectivity, including the cabling.
2
To ping the C-LAN server, type ping ip-address nnn.nnn.nnn.nnn board UUCSS and
press
The variable nnn.nnn.nnn.nnn is the IP address of the TN799DP C-LAN circuit pack
and UUCSS is the cabinet, carrier, and slot of the TN799DP C-LAN circuit pack.
Type ping ip-address nnn.nnn.nnn.nnn board UUCSS and press
3
The variable nnn.nnn.nnn.nnn is the IP address of another computer beyond the gateway
and UUCSS is the cabinet, carrier, and slot of the TN799DP C-LAN circuit pack.
Test Stratum 3 Clock (if used—S8700
Multi-Connect only)
These procedures test the ability of the Stratum 3 clock to correctly provide timing and alarms
to the media server.
!
CAUTION:
The following procedures are destructive to DS1 data and should not be attempted while
DS1 facilities are active.

Check for Red LEDs

Turn on the Stratum 3 clock and wait 40-50 seconds to allow the system to complete the
1
on-board diagnostics before checking LEDs.
If there are any red LEDs, follow the procedures in
2
on page
Stratum 3 Clock LED Indicators
Card
PAI
PAI
PAI
Enter.
200.
LED Label
Procedure
REF A
Check that the CI circuit pack on the left is inserted properly.
Check wiring for DS1 in carrier A which connects the media
gateway to the CSU and the External Synchronization Clock at
the MDF through a Y-cable assembly. If all else fails to clear the
LED then replace the circuit pack.
REF B
Check that the CI circuit pack on the right is inserted properly.
Check wiring for DS1 in carrier B which connects the media
gateway to the CSU and the External Synchronization Clock at
the MDF through a Y-cable assembly. If all else fails to clear the
LED then replace the circuit pack.
ST A
Replace the ST3 card
''Stratum 3 Clock LED Indicators''
May 2002
Enter.