Power Supply Removal; Paper Feed Motor Removal - Epson Stylus Pro 5000 Service Manual

Hide thumbs Also See for Stylus Pro 5000:
Table of Contents

Advertisement

Stylus Pro 5000

4.2.5.6 Power Supply Removal

1. Remove the upper housing. (See section 4.2.1.)
2. Remove the front housing. (See section 4.2.2.)
3. Remove the printer mechanism. (See section 4.2.3.)
4. Remove the fan. (See section 4.2.5.5.)
5. Remove the AC cable from CN1 on the power supply board by
pressing the hook located under the connector.
6. Disconnect CN2 (white) from the main board.
7. Remove 2 screws (CBS, 3×6) securing the power supply to the rear
frame. (See Figure 4-25.)
8. Remove the screw holding the grounding cable to the power supply.
(See Figure 4-25.)
9. Remove 2 screws (CBS, 3×6) securing the power supply to the PF
frame, then remove the power supply. (See Figure 4-25.)
Screws
(CBS, 3×6)
Figure 4-25. Power Supply Removal (top view)
Grounding
cable screw
(not shown)
CN1

4.2.5.7 Paper Feed Motor Removal

1. Remove the upper housing. (See section 4.2.1.)
2. Remove the front housing. (See section 4.2.2.)
3. Remove the printer mechanism. (See section 4.2.3.)
4. Remove the main board shield plate. (See section 4.2.5.4.)
5. Remove the fan. (See section 4.2.5.5.)
6. Remove the power supply. (See section 4.2.5.6.)
7. Remove the print feed motor cable from CN15 on the main board, and
remove the cable from the plastic clip on the PF frame. (See
Figure 4-26.)
8. Remove 2 screws (CBS, 3×6) securing the print feed motor to the left
frame, and remove the print feed motor. (See Figure 4-26.)
Screws, (CBS, 3×6)
Plastic Clip
Figure 4-26. Print Feed Motor Removal
Chapter 4 Assembly and Disassembly
Gear (80)
Combination Gear
(9,6,36)
Print Feed motor
pinion gear
4-15