EPSON Stylus Pro 10000/10000CF/10600
6.
Remove 12 hex head nuts connecting ink pipes, then remove ink pipes.
7.
Remove two screws (M3x8) securing Ink Cartridge Holder.
Figure 4-114.
8.
Remove the ink cartridge holder to the rear side.
Disassembly & Assembly
Thank You For Using TheServiceManualShop.com
Screw
Screw
Thank You For Using TheServiceManualShop.com
4.3.3.10 CR Motor/Pulley ASSY Steel Belt Removal
1.
Remove R Side Cover as described in 4.3.1.4 "R Side Cover Removal".
2.
Remove L Side Cover as described in 4.3.1.5 "L Side Cover Removal".
3.
Release CR Lock, then shift Carriage to center.
4.
Remove Carriage Cover as described in 4.3.3.3 "Replacing the Printhead", Step 5.
5.
Disconnect the CR Motor Cable Connector (locking type).
Figure 4-115. Disconnect Connector
6.
Loosen 2 pulley motion adjustment screws at the L Side Frame, and release the
tension of the Steel Belt.
Figure 4-116. CR Tension Belt
Disassembly
Revision D
Connector
Adjustment Screws
Pulley Driven
CR Steel Belt
164