Mx10003 Router Grounding Specifications; Grounding Points Specifications - Juniper MX10003 Hardware Manual

Universal routing platform
Hide thumbs Also See for MX10003:
Table of Contents

Advertisement

Table 22: Router Environmental Specifications
Description
Altitude
Relative humidity
Temperature
Seismic
Maximum thermal output
(500 W)
NOTE:
Install the router only in restricted areas, such as dedicated equipment rooms and
equipment closets, in accordance with Articles 110-16, 110-17, and 110-18 of the National
Electrical Code, ANSI/NFPA 70.
SEE ALSO
Routine Maintenance Procedures for MX10003 Routers | 116
General Safety Guidelines for Juniper Networks Devices
General Safety Warnings for Juniper Networks Devices | 178

MX10003 Router Grounding Specifications

Grounding Points Specifications

To meet safety and electromagnetic interference (EMI) requirements and to ensure proper operation, the
router must be adequately grounded before power is connected. To ground AC-powered and DC-powered
Value
No performance degradation up to 10,000 ft (3048 m)
Normal operation ensured in relative humidity range of 5%
through 90%, noncondensing
Normal operation ensured in temperature range of 32°F (0°C)
through 104°F (40°C)
Nonoperating storage temperature in shipping container:
–40°F (–40°C) through 158°F (70°C)
Designed to meet Telcordia Technologies Zone 4 earthquake
requirements
1705 BTU/hour