Allen-Bradley Kinetix 6200 User Manual page 52

Modular multi-axis servo drives
Hide thumbs Also See for Kinetix 6200:
Table of Contents

Advertisement

Chapter 2
Plan the Kinetix 6200 and Kinetix 6500 Drive System Installation
52
Resistive Brake Modules
Observe these guidelines when mounting your RBM module:
• Mount circuit components and wiring in the dirty zone or in an external
shielded enclosure. If mounting the RBM module in a separate
ventilated shielded enclosure, run wiring inside metal conduit to
minimize the effects of EMI and RFI.
• Keep unshielded wiring as short as possible. Keep wiring as flat to the
cabinet as possible.
• Route RBM module power and I/O cables separate from other sensitive
low voltage signal cables.
Figure 24 - Noise Zones (RBM mounted above AM power module)
Dirty Wireway
D
Very Dirty LIM/IAM Connections
Segregated (not in wireway)
LIM VAC Input Power
D
D
Line Interface Module
Dirty I/O and Safety Cables
D
D
Motor Brake and Thermal Switch
The thermal switch and brake are mounted inside the motor, but how you
connect to the axis module depends on the motor series.
Refer to Wire the Motor/Resistive Brake (BC) Connector on
wiring guidelines. Refer to Axis Module/Rotary Motor Wiring Examples
beginning on
page 242
combination.
Rockwell Automation Publication 2094-UM002G-EN-P - August 2016
RBM I/O
Motor Power Cables
D
VD
for the interconnect diagram of your drive/motor
Clean Wireway
D
C
Fiber-optic Cable
No sensitive
equipment within
150 mm (6.0 in.).
Kinetix 6200 or
Kinetix 6500 System
Clean I/O, Feedback, and
Ethernet Cables
C
C
page 116
for

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents