117
Overview of Wireless Reader Interfaces
This installation guide is intended for use by technicians who will be installing and maintaining the Wireless
Reader Gateway (LNL-500W).
117.1
Interfaces
The Wireless Reader Gateway interfaces upstream with the Intelligent System Controller. It communicates
downstream with the Schlage Wireless PIM. Only one PIM can be used per wireless reader gateway. One
PIM (panel interface module) supports up to 16 Schlage Wireless readers or locks in many combinations.
The gateway can be used with any address. When configuring the reader in the OnGuard software, a unique
reader number will be specified according to the port and address of the gateway. The first reader MUST
always be present and be identified as reader number 0.
Communications Overview
Intelligent System Controller
Maximum 64 readers / 32 devices
*WRI counts as (1) device
5
4
3
2
1
Wireless Reader
Interface
PIM
Up to 16 wireless
readers/locks
Hardware Installation Guide
Single
Dual
Input/
Reader
Reader
Output
Interface
Interface
Control
Module
Module
Module
661