Lenel OnGuard Hardware Installation Manual page 323

Table of Contents

Advertisement

Error condition
Boot loader loading firmware
file
Invalid EFL file
Invalid Xmodem packet
Invalid Application firmware
for module CPU
Invalid Boot firmware for
module CPU
Firmware update failed
No valid primary firmware
copy
No valid backup firmware
copy
No valid manufacturing
parameters
Flashing
Description
pattern
2 Red,
Console boot loader is loading a firmware file.
2 Green
1 Red,
The EFL specified to be loaded using the console
2 Green
loader is not a valid EFL file.
1 Red,
The console loader received an invalid Xmodem
1 Green
packet and terminated the firmware download
operation.
3 Red,
The module is not operational. Application
0 Green
firmware loaded on the module will not run
properly. Requires new firmware be loaded using
the console boot loader or the module must be
returned for repair.
2 Red,
The module is not operational. Boot loader
3 Green
firmware loaded on the module will not run
properly. The module must be returned for repair.
1 Red,
Firmware update operation was unsuccessful. Retry
3 Green
and if it fails continuously, load a different
firmware file.
3 Green,
The firmware flash contains 2 copies of the
2 Red
application firmware. The primary copy is not valid
so the backup copy will be loaded into the primary
copy and executed.
3 Green,
The firmware flash contains 2 copies of the
1 Red
application firmware. The backup copy is not valid
so the primary copy will be loaded into the backup
copy.
3 Green,
The manufacturing parameters which include the
0 Red
serial number, etc. are invalid. The module must be
returned for repair.
Hardware Installation Guide
323