Biometric Readers
c.
On the Wiegand tab, set the Pass-Thru Format. Enable Input and Selective Output under Wiegand
I/O.
With OnGuard 7.3, Alarm Monitoring has the capability of displaying biometric mismatch events.
If you are planning to enable the Biometric Mismatch capability:
Select the Pre-Defined Format radio button.
In the format drop-down list, select Lenel64. This custom format can be found on the
Supplemental disc. Click [Upload Custom Format] and navigate to the Lenel64.wgf file (found
on the Supplemental disc) to select it.
The card format corresponding to the Lenel64 custom format must be 64 bits long. The issue
code start bit should be 56, and the number of bits should be 8. Bits 0 through 55 can be
configured in any way you choose. The recommended format is Lenel 64-bit Wiegand (0/8, 8/
48, 56/8).
In the On Failure section, check the box for Fail Site Code. Enter the code (254) next to it.
644 —