LNL-1100-U Input Control Module
50

Wiring

Wire inputs I1 through I16 (J9 - J16) using a twisted pair cable, 30 ohms maximum, 24 AWG minimum.
Note:
For UL installations, refer to section
Note:
For termination resistor values, refer to the
50.1

Supervised (Software Configurable) Alarm Inputs

The sixteen (16) inputs that are available on the ICM are software configurable alarm inputs that can be used
for alarm device monitoring. Each of these inputs can be configured, via the Access Control software, as
either N/O (normally open) or N/C (normally closed) in combination with either supervised or unsupervised
wiring. These alarm inputs are connected using Inputs 1 - 16.
290 —
revision 7
UL Listed Installations
ICM input wiring
Input Resistor Table
on page 296.
on page 291.