Dip Switch/Jumper Setting - Lenel OnGuard Hardware Installation Manual

Table of Contents

Advertisement

LNL-2010W/2020W/2020W-NDK/NDKV2 Magnetic Card Access Reader
Format T
(factory test) magnetic data output: verify track 2 data and send track 2 data without
formatting using clock data signaling. Zero trim, reverse read, bad card filter, and tamper
monitor option are enabled.
100.2

DIP Switch/Jumper Setting

All readers are equipped with DIP switches for configuration/parameter setting. DIP switches are set by
moving the slide to on/off position using a small tool (may be made from a paper clip). Remove the top
mounting bracket to access the DIP switches.
The DIP switches/jumpers on the LNL-2010/2020 reader are used to select a preset format. This preset
format determines how the card is interpreted, the functions for the LED and buzzer, and the output signal
format, etc. Refer to format specification for details.
Switch/Jumper Position
FORMAT
4
format 0
ON
format 1
ON
format 2
ON
format 3
ON
format 4
ON
format 5
ON
format 6
ON
format 7
ON
format T (factory
off
reserved)
482 —
revision 7
DIP SWITCH
3
2
1
ON
ON
ON
ON
ON
off
ON
off
ON
ON
off
off
off
ON
ON
off
ON
off
off
off
ON
off
off
off
off
off
off