Configuration In Secureadmin - Lenel OnGuard Hardware Installation Manual

Table of Contents

Advertisement

b.
In the following example, the 4G reader is using COM7. Your setup may be different.
2.
Start the SecureAdmin software and log in.
3.
On the Network tab, click Register via Client. Configure the following settings:
a.
Port: Select the port number to which the device is connected. See step 1.
b. Baud Rate:
If you are using the reader for enrollment/capturing, select 115200.
If you are using the reader for verification, select 38400.
c.
Device ID:
If you are using the reader as an enrollment/capture device, the ID should be 0.
If you are using the reader for verification, start with ID0 and increment the ID for each
additional device on the RS-485 bus.
Click [Next].
4.
Verify the device information and server communication parameter. Click [Next].
5.
Type in a device name. Do not change the group. Click [Register].
6.
Information will be displayed in the device summary. Click [OK].
115.3
4G Configuration in SecureAdmin
After the reader has been registered, you will need to configure the following parameters.
1.
In SecureAdmin, on the Device Settings tab, navigate to your reader under Device Network > Default
Group. Double-click on the reader.
Hardware Installation Guide
609