Installation; Wiring And Setup - Lenel OnGuard Hardware Installation Manual

Table of Contents

Advertisement

67

Installation

To install the intelligent single door controller, perform the installation procedures described in the
following sections, in the order in which they are presented.
1.
Wire the device for communication.
2.
Wire readers.
3.
Wire the input circuit.
4.
Wire the relay circuit.
5.
Supply power to the controller.
6.
Configure the correct settings using the jumpers and DIP switches.
7.
Set the board for the desired initial IP addressing mode.
Important:
67.1

Wiring and Setup

Refer to the following table for wiring and setup of the LNL-1300e.
Connections
TB1-1
IN1
TB1-2
IN1
TB1-3
IN2
TB1-4
IN2
TB2-1
IN3
TB2-2
IN3
TB2-3
IN4
TB2-4
IN4
TB3-1
VO
TB3-2
LED
In order to help prevent damage from electrostatic charges or other transient
electrical surges, connect earth ground to the panel at the screw next to the
Ethernet Connector before making other connections. Recommended earth
ground references are a grounding rod or a cold water pipe. The mounting hole
next to the Ethernet jack is connected to the case of the Ethernet jack and other
Ethernet transient suppression devices. Your grounding connection must be made
at this point. The system should be connected to earth ground at one point and
one point only.
Input 1 (typically door contact)
Input 2 (typically request to exit)
Input 3
Input 4
Reader 1 Power Output – 12 VDC
Reader 1 LED Output
Hardware Installation Guide
357
revision 7 —

Advertisement

Table of Contents
loading

Related Products for Lenel OnGuard