ISC Communications
Configuring UDS-10 to ISC 4-Wire (232)
ISC:
Communications Interface Type = RS-232
RS-232 Type = 4-Wire RS-232
(Refer to ISC documentation for more information )
A CDC
A C
GND
GND
I N2
GND
I N1
Intelligent System
Controller (1000 )
LI THI UM
3V
B R2325
P N
238 —
revision 7
485 232
J 8
J 7
J 15
J1
A
B
C
J 16
J 17
J 18
U15
2 M E G
U17
U16
RE V
S N
25-Pin Female Serial Connector
Pin 2
TX D
TR1+
Pin 3
RX D
TR1-
RTS
Pin 4 & 5
R1+
CTS
R1-
GND
Pin 7
TR2+
TR2-
GND
TR3+
TR3-
GND
TR4+
TR4-
GND
TR5+
TR5-
GND
S 1
J5
To LAN
10 Base T
6 VDC
Lantronix