104.2.3
Wiring the LNL-1300-U
From LNL-1300-U
Reader
Pin
Terminals
GND
J10
DAT D0
CLK D1
LED1
LED2
J13
BZR
V0
Note:
Connect reader's cable drain shield to earth ground.
104.2.4
Wiring the LNL-1320-U
From LNL-1320-U
Reader
Pin
Terminals
GND
J10
DAT D0
CLK D1
LED1
LED2
J13
BZR
V0
Note:
Connect reader's cable drain shield to earth ground.
To OpenCard XF1050-K Reader
Wire
Black
Ground
Green
Clock/D0
White
Data/D1
Orange
Green LED
Brown
Red LED
Blue
Buzzer Input
Red
Power (5-12 VDC)
To OpenCard XF1050-K Reader
Wire
Black
Ground
Green
Data/D1
White
Clock/D0
Orange
Green LED
Brown
Red LED
Blue
Buzzer Input
Red
Power (5-12 VDC)
Hardware Installation Guide
Typical Software Settings
Description
Reader Type =
Wiegand/Prox
LED Mode = 2-Wire
LED Control
Typical Software Settings
Description
Reader Type =
Wiegand/Prox
LED Mode = 2-Wire
LED Control