Device
HID Wiegand
SRE-3100500
SRE-3100130
SRE-3102500
HID iCLASS
6100
6110
6120
6130
6111
6121
6131
6125A
Lenel OpenCard
LNL-XF1100D
LNL-XF2100D
LNL-XF2110D
Typical door strike power is estimated at 24 VDC, 300 mA, consult manufacturer specifications for actual
values.
Note:
Device power requirements are subject to change without notice. These tables are intended
only as a guide.
FIELD HARDWARE POWER SUPPLIES AVAILABLE
Part #
LNL-AL400ULX
LNL-400X-CE220
28 —
revision 7
Power Required
5-12 VDC, 40 mA
5-12 VDC, 40 mA
5-12 VDC, 60 mA
10-16 VDC, 80-300 mA @ 12 VDC
10-16 VDC, 80-300 mA @ 12 VDC
10-16 VDC, 80-260 mA @ 12 VDC
10-16 VDC, 72-244 mA @ 12 VDC
10-16 VDC, 80-300 mA @ 12 VDC
10-16 VDC, 100-350 mA @ 12 VDC
10-16 VDC, 72-244 mA @ 12 VDC
5-12 VDC, 70-120 mA @ 12 VDC
6-16 VDC, 95-254 mA
8-16 VDC, 95-218 mA
8-16 VDC, 120-215 mA
Description
UL Listed power supply - 12 VDC (4A output, 9.7 - 13.5 VDC, 12 VDC
nominal), 120 VAC input, continuous supply current with enclosure, lock,
UPS capable (battery optional). Operating temperature: 0° to +49° C (32° to
120° F). Humidity: 0 to 85% RHNC. BTU output: 33 BTU.
CE marked power supply - 12 VDC (4A output), 230 VAC input, continuous
supply current with enclosure, lock, UPS capable (battery optional).
Operating temperature: 0° to +49° C (32° to 120° F). Humidity: 0 to 85%
RHNC. BTU output: 33 BTU.