Firmware download is only supported for models and versions of Lenel hardware.
Firmware Download Capabilities (for current version of OnGuard)
Module
Controller (LNL-500,
1000, 2000)
Controller (LNL-4420,
3300, 2220, 2210)
Input Control Module
(LNL-1100) Series 2
Output Control Module
(LNL-1200) Series 2
Single Reader Interface
Module (LNL-1300)
Series 2
Single Door IP
Interface Module
(LNL-1300e)
Dual Reader Interface
Module (LNL-1320)
Series 2
Command Keypad
(LNL-CK)
Gateways (LNL-500B,
500W)
The most current version of the firmware is shipped with your OnGuard software and was installed during
the initial software installation. Each subsequent software release you receive will also include the most
current version of the firmware.
Is firmware
Requirements
download
supported?
Yes
Firmware version 3.1xx or later is recommended
Yes
Firmware version is 1.2xx or later.
Yes
Firmware version is 1.3xx or later.
Yes
Firmware version is 1.3xx or later.
No
Currently, firmware version 1.5xx or later.
Yes
Firmware version 1.6xx or later is recommended.
Yes
Firmware version is 1.5xx or later, and the board is rev. B.
No
Firmware version 1.63 (factory firmware upgrades only).
This firmware cannot be upgraded in the field.
Yes
These have other firmware requirements, depending on their
downstream devices.
For Bioscrypt V-Series readers, the LNL-500B requires
firmware version 1.26.
For HandKey readers, the LNL-500B requires firmware
version 1.25.
To use wireless readers, the LNL-500W requires
firmware version 1.10.