For the Dual Reader Interface Module, make sure that jumper J2 is set to unregulated power mode.
This will allow the maximum amount of current for the readers.
Wiring the LPSR-2400 and the LNL-1320
From LNL-1320
Reader 1 or Reader 2 Pin
GND
DAT D0
CLK D1
BZR
LED
V0
Wiring the LPSR-2400 and the LNL-1320-U
From LNL-1320-U
Reader
Pin
Terminals
GND
J10
DAT D0
CLK D1
LED1
LED2
J13
BZR
V0
4.
Use a linear and regulated power source, between 5 volts (40 mA peak) and 12 volts DC (70 mA peak).
5.
Install the reader on the door frame or other surface. Attach the reader to the door frame with supplied
screws or with adhesive or sealant.
6.
Power up the reader. The LED is steady amber. (The beeper does not sound.)
7.
Present any Lenel proximity credential (card, keytag, or wafer) briefly to the reader. The beeper sounds
a single short beep. The LED is then steady red to indicate standby mode. The reader is now initialized
and prepared to read cards.
Note:
All credentials must be Lenel's products.
8.
The LED color in standby may be changed from red to green, or from green to red, using a Color
Changer card, available from Lenel. Remove power from the reader for a few seconds, then restore
power. While the LED is amber, present the Color Changer card to toggle the LED color at standby.
To LPSR-2400 Reader
Wire Color
Black
Green
White
Yellow
Brown
Red
To LPSR-2400 Reader
Wire Color
Black
Ground
Green
Data 0
White
Data 1
not connected
not connected
Brown
Green LED
Yellow
Buzzer
Red
5-12 VDC
Hardware Installation Guide
Typical Software Settings
Description
Ground
Data 0
Data 1
Beeper
LED
5-12 VDC
Description
Reader Type =
Wiegand/Prox
Keypad = No Keypad
LED Mode = 1-Wire
LED Control
Typical Software Settings
Reader Type =
Wiegand/Prox
Keypad = No Keypad
LED Mode = 1-Wire
LED Control